TOP

Back to Paralled Shaft Gear Motor

Paralled Shaft Reduction Gear Motor

prostar logo white_工作區域 1.png

Exploded View

Exploded view
Prostar PSHGM_1 Exploded view.jpg
Prostar PSHGM_1_Exploded view.png

For a clearer picture display, please visit computer version of the website.

Series Code

Parallel Shaft Gear Motors

Prostar PSHGM_2 Series code_1.jpg

Ordering example :

HM4-22 F O -1k5/4P 5-38 B

For a clearer picture display, please visit computer version of the website.

Parallel Shaft Gear Units

JM2-JM7 :

With adapter for mounting IEC motors

Ordering example :

JM4-22 F O 200-90

Prostar PSHGM_2 Series code_2.jpg

For a clearer picture display, please visit computer version of the website.

Series code

Lubricant Selection Table

Lubricant selection table

Lubrication : ProSTAR supplies ISO VG320 oil in the condition of ambient  temperature -10°C~+40°C if there is no special arrangement made by customers.

Lubricant Selection Table : 

Prostar PSHGM_9_Oil.png

Remark:

  1. It is used in the condition of ambient temperature -30°C~+10°C

  2. It is used in the condition of ambient temperature -25°C~+80°C

Prostar PSHGM_9_Type.png

Lubricant change:

  1. Do not mix different kinds of oil together.

  2. For the first time of maintenance, replace gearbox oil after 4000 operating hours or 6 months, whichever comes first.
    After that, evety time while the operating hour reaches 10000 hour, the gear box oil must be replaced again. Please refer to the oil quantity table given above.

  3. If using in special conditions, such as heavy-duty, high temperature, etc.,please refer to the lubricant selection table as above.

Notice : After finishing mounting, please remove threaded plug on the top of gearbox and put into the breather plug before operation.

Brake

Motors can be optionally supplied with a built -in spring loaded disc brake at the end of the motor. The braking force of the spring loaded brake is developed mechanically by spring action, so it can used (with additional parts) as safety brake for the purpose of complying with accident prevention regulations. 

The brakes are operated electrically via D.C. excitation. For connection with single phase A.C., the brake motors need to be equipped with a rectifier. In this case, the supply voltage must be provided while ordering.

All spring loaded disk brakes can be supplied with manual release on request. The manual release is used while the power is unavailable. In order to keep the brake in good condition, the air gap variation of the brake needs to be paid attention. Braking torques refer to a speed n = 100rpm. The materials of all brake linings are asbestos free.

Prostar PSHGM_9_Brake.png
Brake
bottom of page